GENERAL DESCRIPTION |
TECHNICAL SPECIFICATIONS | |
OPERATING CONDITIONS | |
Power Supply | |
Mains voltage | 380V/220V 3-phase+neutral, +5% -10% |
Power input (fm=1kHz/m=1) | 110 kVA, max |
Mains frequency | 50 Hz or 60 Hz (as option) |
Power factor | > 0,95 |
Modulator Input | |
Input impedance | 2000 Ohms balanced standard 600 Ohms balanced as option |
Input level (for fm=1 kHz, m=1) (0 dBm 0.775V across 600 Ohms) | -10 dBm to +10 dBm |
Transmitter Output | |
RF output load impedance | 50 ohm unbalanced, 300 ohm balanced, as option |
Permissible VSWR | s < 2 at 50 ohm unbalanced |
Climatic Conditions | |
Temperature in transmitter hall | +1 to +45 °C |
Max. altitude above sea level | 2000 m |
Relative humidity | < 95 % |
ELECTRICAL CHARACTERISTICS | |
Frequency Range | |
Frequency range | 3.2 - 26.1 MHz |
RF Output Power | |
Output power in the range | 50 kW carrier in A3 mode |
Frequency stability | 10-8 Hz/day |
Type of modulation | High level plate modulation |
Modulation principle | SSDM |
Type of emission | A3E (AM) H3E (SSB with -6dB carrier reduction, as option) R3E (SSB with -12dB carrier reduction, as option) DSB with ACC (as option) |
Modulation Characteristics | |
Max. permitted ratio of input to output as function of modulation depth up to m=80% | ±0.5 dB |
Modulation capability: 50 Hz - 7.5 kHz | m=100% sine, continuous |
Frequency response | ±1 dB 50 Hz - 7.5 kHz, reffered to 70% - 1 kHz |
THD + Noise | < 3.5% m=30% - 90%, f=50 Hz - 7.5 kHz |
Modulator efficiency | > 95%, m=0-100%, f=50 Hz - 7.5 kHz |
Signal to Noise Ratio | |
Unweighted | less than 55 dB Reference level m=100% fm=1 kHz,sinusoidal, mains voltage sinusoidal |
RF Harmonic and Spurious Radiation | |
RF Harmonic and Spurious Radiation | < -60 dB |
Carrier Shift | |
Carrier shift at m=95% with fm=1 kHz sine shaped and at constant mains voltage referred to the unmodulated carrier |
< 5% |
Overall Efficiency | |
Carrier with 0 - 100% modulation | > 70% |
Max. Tuning Time | |
Max. tuning time | 30 sec. |
Specifications may change without notice |
TUBE COMPLEMENT | |||
RF stages | AF stages and modulator | ||
Number | Type | Number | Type |
1 | 4CM100,000A |
THIS TYPE OF TRANSMITTER IS INSTALLED IN THE FOLLOWING COUNTRIES | |||||
ITU | Country | ITU | Country | ||