GENERAL DESCRIPTION |
TECHNICAL SPECIFICATIONS | |
R.F Data | |
Power output | 3 kW |
Output impedance | 50 omhs unbalanced |
VSWR | up to 3:1 |
Frequency range | 2.0 to 30 MHz |
Frequency changetime autotune | 5s maximum |
Facility | Frequency follow |
R.F harmonics | Less than 50 mW |
Spurious radiation | Less than 50 mW |
Phase stability | Typically 3° r.m.s in 10 ms Sampling taken 3s or more after frequency change |
Frequency standards | i) Internal Temperature-Controlled Crystal Oscillator (TCXO), ±1 p.p.m/year, ±1 p.p.m 0°C to 60°C with an internal adjustment capability to take up to 10 years ageing. ii) With internal standard, 1 part in 108 per day. Less than 1 part in 107 over temperature range -10°C to +55°C. Long term - typically 1.5 parts in 107 per month after one month. Warm up time - 7 min at 20°C for ±5 parts in 108 of nominal or previous setting. iii) With optional higher stability internal standard, 5 parts in 1010 per day. Less than 1 part in 108 over temperature range -10°C to +55°C. Long term - 1.5 parts in 108 per month. Warm up time - 20 mins at 25°C to within 2 parts in 108 of final frequency. iv) With external standard, will not derate long term stability characteristics of applied external standard. Standard frequency of 1 MHz at a level of 50 mV to 2.5 V r.m.s in 50 ohms. |
Modulation Data | |
A.F input impedance | 600 ohms balanced |
A.F input level | +6 dBm to -30 dBm |
A.F response Transmitter set to 70% modulation at 400 Hz |
±1 dB 60 Hz to 4000 Hz -1.5 dB 4000 Hz to 5000 Hz -2 dB 5000 Hz to 6000 Hz |
A.F distortion Over the range 60 Hz to 6000 Hz |
At 50% modulation, better than 1.5% At 90% modulation, better than 2.5% |
Noise | 55 dB unweighted, below 100% modulation at 400 Hz |
Modulation capability | 100% continuously (with sinewave 60 Hz to 6000 Hz) |
Electrical Data | |
Power supplies | Drive 100-250 V +10% -10% 45 to 65 Hz. Amplifiers 380-440 V +6% -10% 3 phase 4 wire a.c 50/60 Hz ±2%. Frequency tolerance ±2 Hz. |
Environmental Data | |
Temperature | -10°C to +55°C at sea level |
Relative humidity | 95% at 40°C at sea level |
Temperature range at 2000 m | -10°C to +50°C. for operation above 2000 m a booster fan is required to maintain temperature range. |
Mechanical Characteristics | |
Drive Cabinet | Width : 600 mm Height : 1600 mm Depth : 700 mm |
Amplifier | Width : 1500 mm Height : 1600 mm Depth : 700 mm |
Specifications may change without notice |
TUBE COMPLEMENT | |||
RF stages | AF stages and modulator | ||
Number | Type | Number | Type |
? | ? | ? | ? |
THIS TYPE OF TRANSMITTER IS INSTALLED IN THE FOLLOWING COUNTRIES | |||||
ITU | Country | ITU | Country | ||
I | ITALY | CLN | SRI LANKA |