TECHNICAL SPECIFICATIONS |
TRANSMITTER RF PERFORMANCE |
Frequency range |
4.9 to 22 MHz |
Wavelength bands |
13m, 16m, 19m, 25m, 31m, 41m, 49m and 60 meters |
Ouput power |
100 kW |
Output impedance |
300 ohms balanced |
Spurious Outputs |
Meets FCC and CCIR Specs. (-80 dB max.) |
Carrier shift |
Less than 2% at 100% modulation |
Balun |
External overhead, 75 to 300 ohms |
AUDIO PERFORMANCE |
Type of modulation |
Amplitude, Solid state; 64 stepped modules, 120% at 50 to 5000 Hz |
Input impedance |
600 ohms + 10 dBm for 100% modulation |
Freq. response |
+1/-2 dB from 50 to 5000 Hz for 95% modulation at 1 kHz reference |
Audio distortion |
Less than 2% from 50-2000 Hz at 95% modulation. Less than 3 % to 5000 Hz at 85% modulation. |
Audio noise |
-50 dB or better below 100% modulation |
Transient resp. |
Zero tilt after clipping. High frequencies attenuated 2 dB at 5 kHz to minimize overshoot. |
TUNING |
Type |
Automatic with servo motors & presets within bands. |
Rate |
Frequency and band change within 30 seconds |
SERVICES REQUIRED |
Connect power |
480 Vac - 3Ph @ 220 amps maximum demand 120 Vac - 1Ph |
Power Factor |
> 90 % |
Compressed air |
60 - 100 psi (Flow only at turn-on/turn-off) |
POWER CONSUMPTION |
Consumption at % modulation |
0 % : 147 kW 30 % : 154 kW 100 % : 220 kW |
Overall Efficiency |
72 % |
CONTROL |
Control Panel |
Analog and Video metering presentations with push button and keypad operation and data input. |
Control System |
Computerized, based on the Motorola 68000 CPU |
OPERATING ENVIRONMENT |
Humidity |
95% Max. |
Temperature |
0 to 50 degrees C |
Local location |
Indoor operation |
Altitude |
Operable to 10,000 feet above sea level |
CABINET DIMENSIONS |
Height |
130" |
Width |
119" |
Length |
112" |
No. of units |
Two units (for shipping) 113"L x 83"H x 46"W each |
Specifications may change without notice |